GB-17
Please check the following before calling for service.
1. Power Supply
Check the power plug is properly connected to a suitable wall outlet.
Check the line fuse/circuit breaker is functioning properly.
2. When the door is opened:
A. Does the oven lamp light? YES _____ NO ______
B. Does the cooling fan work? YES _____ NO ______
(Put your hand over the rear ventilation opening.)
3. Place one cup of 150 ml water in the oven and close the door securely.
Touch these keys.
A. Does the cook indicator go on? YES _____ NO ______
B. At the end of this time, is the water warm? YES _____ NO ______
If "NO" is the answer to any of the above questions, call your dealer or an authorized SHARP Service Agent and
report the results of your check.
1 0 0
Door
To remove all trace of dirt, regularly clean both sides
of the door, the door seals and adjacent parts with a
soft, damp cloth. Do not use abrasive cleaner.
Air intake fi lter
SERVICE CALL CHECK
Keep clean the air intake fi lter. To clean the air intake
lter you have to pull the two clips on the fi lter and to
remove the air intake fi lter. Wash the air intake fi lter in
mild soapy water and dry with a soft cloth. After clean-
ing re-install the air intake fi lter to the oven. Clean the
air intake fi lter once every two weeks.
CAUTION:
DO NOT OPERATE THE OVEN WITHOUT THE
AIR INTAKE FILTER IN PLACE.
Hole
Oven
Hole
Clip
Air intake fi lterClip
R23AT_OM_NORDIC_5_EN_SE_NO_FI_DK17 17R23AT_OM_NORDIC_5_EN_SE_NO_FI_DK17 17 2013-12-02 11:15:122013-12-02 11:15:12

Other manuals for Sharp R-23AT

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sharp R-23AT and is the answer not in the manual?

Sharp R-23AT Specifications

R-23AT

Power IconPower
AC line voltage230 V, 50 Hz, single phase
distribution line fuse/circuit breaker16 A (time lag)
AC power required2.9 kW
output power1800 W (IEC 60705)
microwave frequency2450 MHz
Capacity IconCapacity
oven capacity20 litres
cooking uniformityrotary antenna system
Weight and Dimensions IconWeight and Dimensions
outside dimensions (single oven)510 mm (W) x 335 mm (H) x 470 mm (D)
cavity dimensions330 mm (W) x 180 mm (H) x 330 mm (D)
weight33 kg

R-25AT

Power IconPower
AC line voltage230 V, 50 Hz, single phase
distribution line fuse/circuit breaker16 A (time lag)
AC power required3.15 kW
output power2100 W (IEC 60705)
microwave frequency2450 MHz
Capacity IconCapacity
oven capacity20 litres
cooking uniformityrotary antenna system
Weight and Dimensions IconWeight and Dimensions
outside dimensions (single oven)510 mm (W) x 335 mm (H) x 470 mm (D)
outside dimensions (two ovens)510 mm (W) x 670 mm (H) x 470 mm (D)
cavity dimensions330 mm (W) x 180 mm (H) x 330 mm (D)
weight33 kg