EasyManua.ls Logo

Sharp R-343WM - Page 7

Sharp R-343WM
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
R343M - 7
To protect the electronic circuits, this model is provided with a fine foil pattern added to the input circuit on the PWB, this foil
pattern acts as a fuse. If the foil pattern is open, follow the troubleshooting guide given below for repair.
Problem: POWER ON, indicator does not light up.
STEPS OCCURRENCE CAUSE OR CORRECTION
1 The rated voltage is not applied between Pin Check supply voltage and oven power cord.
No. 5 of the 3 pin connector (A) and the
common terminal of the relay RY2.
2 Only pattern at "a" is broken. *Insert jumper wire J1 and solder.
3 Pattern at "a" and "b" are broken. *Insert the coil RCILF2003YAZZ between "c" and "d".
NOTE: *At the time of making these repairs, make a visual inspection of the varistor. Check for burned damage. If
any abnormal condition is detected, replace the defective parts.
TEST PROCEDURES (CONT'D)
PROCEDURE
LETTER
COMPONENT TEST
D PROCEDURES TO BE TAKEN WHEN THE FOIL PATTERN ON THE PRINTED WIRING BOARD
(PWB) IS OPEN
15
RY2
(J1)
a
d
c
b
CN-A
RY1
D1
VRS1
D71
ZD71

Related product manuals