34
VC-A592U/A593U
VC-A5933U/H992U
VC-H993U/H994U

0
5
10
15
20
25
F mechanical timing
Mode
Rotation angle
Mode check
Cam mark
Mode detection outside
(D709 SW B)
Mode detection inside
(D708 SW A)
Cam graph E
60 120 180 240
300 360
CA/END
CS/EJ
33.82
UL
81
VSR
218
PU(LD)
188
PB
252
SLOW
269 293
FF
309
STOP
325
Cam switch
0
Mode detection outside
Mode detection inside
S sensor
S sensor
Mode detection inside
Sensor A
Mode detection outside
Sensor B
CS/EJ
ULD
PU LD
VSR
PB
STILL
FF
STOP
1
1
1
0
0
0
0
0
0
1
1
1
0
1
0
0
open
close
0
1
EJ
UL
STOP
PU
0
1
1
0
0
0
1
0
1 or 0
1
1
1
00
100000
1
1
1
1
1
1
VSR
PB SLW
FF

Loading motor turns in reverse
direction and master cam
counterclockwise.
CASSETTE INSERTION STOP
Cassette
inserting
Full-
loading
YES
YES
YES
NO
NO
NO
Unloading
Loading motor starts in normal
direction and master cam counter
clockwise.
Does mechanism position sw.
come off within 2.5 sec.?
Are start/end sensors at low level
before cassette insertion ?
Insert cassette.
Double action rack slides.
Drum motor starts.
Tape loading.
Pinch roller comes into contact.
Cam switch is at PB position.
Loading motor stop.
Is drum FG pulse outputted ?
End
End
Cassette is ejected and loading
motor stops.
Start sensor close.
(Cassette is judged
caught halfway.)
(Cassette LED or some other part
is judged defective.)
6. MECHANISM OPERATION FLOWCHART AND TROUBLESHOOTING GUIDE
MECHANISM OPERATION FLOWCHART
* This flowchart describes the outline of the mechanism’s operation, but does not give its details.