(4)Camera signal system adjustment mode
In the camera signal system adjustment mode, the automatic white balance is disabled to allow for the adjustment of the camera
unit. At this time, the white balance mode is fixed at the INDOORS mode and the focus mode is switched to the manual focus mode.
1) Shifting to the camera signal system adjustment mode
Set the data for the address "0000" to " 00".
]
This shifts the camera signal system adjustment mode.
* When this adjustment mode has been shifted to, make the adjustment according to (5) Camera unit adjustment procedure.
2) Shifting to the normal operation mode
Set the data for the address "0000" to " FF".
]
This shifts the mode to the normal operation mode.
]
Press the "CONTINUE" key, and the "CAM ADJ" display goes out of the screen, enabling the normal operation.
(5)Camera unit adjustment procedure
2. Iris, ND Meter basic adjustment
1. Auto focus adjustment
7. White balance adjustment
8. Indoor white gain adjustment
9. Color gain adjustment
3. Black balance adjustment/A/F noise adjustment
4. Iris AE coarse adjustment
11. Outdoor white gain adjustment
12. Iris AE adjustment
5. White balance coarse adjustment
6. Color gain coarse adjustment
10. Auto white balance adjustment
* The above 1. Auto-focus function adjustment in the auto-focus function adjustment mode, whereas the other adjustments are made
in the camera signal system adjustment mode.
(6) Replacement procedure of gyro unit
1) When replacing E
2
PROM on lens unit of camera head with the gyro unit not replaced
Since the adjustment data of gyro is written in E
2
PROM, copy the data of addresses "0864, 0865, 0866, 0867" and rewrite them
after replacement.
2) When replacing the gyro sensor: RMC1001, RMC1002
After replacing with the specified gyro sensor, write the following data in the addresses "0864, 0865, 0866, 0867".
Ref No. Part code Address Data
RMC1002 Replacement with RSNSG0004CEZZ
0864 02
0865 30
RMC1001 Replacement with RSNSG0013CEZZ
0866 04
0867 00