5-10
3-6) CPU version PRINT
a. Test Procedure
The CPU version is printed with above key operation.
This mode is finished automatically when print completed.
b. Test result print
(When Version 1.00)
← CPU Version No.
← 06
3-7) MEMORY BATTERY VOLTAGE SENSOR TEST
a. Test Procedure
Displays A/D conversion port read value of memory battery.
To terminate the test, press any key.
<The displayed value and status>
0155 or greater
Normal
0154 or smaller Low battery display
0138 or smaller
No battery display
(MRS is done when power on)
b. Test result print
3-8) TIME DISPLAY TEST
a. Test Procedure
Displays time of CPU with above key operation.
<Check point>
1. To blink the ā€œ-ā€œ (hyphen)
2. To count up the clock
To terminate the test, press any key.
b. Display
c. Test result print
3-9) DESTINATION DISPLAY
a. Test Procedure
The following destination code in the firmware is displayed with
above key operation.
North America
EU
Japan
Display
0
1
2
To terminate the test, press any key.
b. Display
c. Test result print
Hour
Minute
Second
Blinking per 0.5sec
0100
06
07
yymmdd-hhmmss
08
09

Other manuals for Sharp XE-A137