TROUBLESHOOTING
If a condition listed below occurs, please check the following items before calling
customer service.
Symptom
Inspection
Solution
The unit is
not
operating.
Check the power connection is
secure.
Insert the power cord securely into
the wall
Outlet.
Check if the water level indicator
lights up?
Empty the drain pan by removing
the rubber plug.
Check the room temperature.
The range of operating
temperature is 5-35℃.
The unit
works with
reduced
capacity.
Check the air filter for dirt.
Clean the air filter as necessary.
Check if the air duct is blocked.
To clear the obstacle.
Check if the room door or window
is open.
Keep the door and windows closed.
Check if the desired operating
mode is selected and the
temperature is properly set.
Set the mode and temperature at
the proper set-point according to
the manual.
The exhaust hose is detached.
Make sure the exhaust hose is
securely attached.
Water
Leakage
Overflow while moving the unit.
Empty the water tank before
transport.
Check if the drain hose is kinked
or bends.
Straighten the hose to avoid a trap
existing.
Excessive
Noise
Check if the unit is securely
positioned.
Place the unit on horizontal and
firm ground.
Check if any loose, vibrating parts.
Secure and tight the parts.
The noise sounds like water
flowing.
The noise comes from flowing
refrigerant. This is normal.
Error
Codes
E0
Communication faults between
the main PCB and display PCB.
Check the wire harness of the
display PCB for damage.
E1
Ambient temperature sensor
failure
Check connection or replace it. To
clean or replace the temperature
sensor.
E2
Coil temperature sensor failures.
Check connection or replace it. To
clean or replace the temperature
sensor.
Ft
Condensate water high-level
alarm.
Empty the drain pan by removing
the rubber plug.