20694376C
INSTRUCTION MANUAL
User’s System Guide
SPECTROPHOTOMETER
UV-2401 PC (P/N 206982201/206-55670)
UV-2501 PC (P/N 206-82251/206-55674)
I
Read the instruction manual thoroughly before you use the product. Keep
I
I
this instruction manual with care so that you can use it any time you need it.
I
I
I
SWIMADZU CORPORATION
ANALYTICAL INSTRUMENTS DlVlSlON
KYOTO, JAPAN
Question and Answer IconNeed help?

Do you have a question about the Shimadzu UV-2501 PC and is the answer not in the manual?

Summary

Precautions for Safe Operation

General Safety Precautions

Key safety guidelines for operating the spectrophotometer, covering usage, modification, and repair.

Chapter 1 Inspection

Chapter 2 Installation

2.1 Hardware Installation

Provides step-by-step instructions for setting up the UV-2401/2501 PC instrument and associated software.

Chapter 4 Maintenance and Checking

4.2 Troubleshooting

Provides guidance on identifying and resolving common initialization and scanning problems.

4.3 Replacement of the Light Source

Details the specifications and step-by-step procedure for replacing the WI and D2 lamps.

4.4 Replacement of the Fuses

Explains the procedure for replacing fuses, including safety precautions and correct fuse types.

Chapter 5 Specifications

5.1 UV-2401;2501 PC Specifications

Presents detailed technical specifications for the UV-2401/2501PC spectrophotometer, including performance data.

Summary

Precautions for Safe Operation

General Safety Precautions

Key safety guidelines for operating the spectrophotometer, covering usage, modification, and repair.

Chapter 1 Inspection

Chapter 2 Installation

2.1 Hardware Installation

Provides step-by-step instructions for setting up the UV-2401/2501 PC instrument and associated software.

Chapter 4 Maintenance and Checking

4.2 Troubleshooting

Provides guidance on identifying and resolving common initialization and scanning problems.

4.3 Replacement of the Light Source

Details the specifications and step-by-step procedure for replacing the WI and D2 lamps.

4.4 Replacement of the Fuses

Explains the procedure for replacing fuses, including safety precautions and correct fuse types.

Chapter 5 Specifications

5.1 UV-2401;2501 PC Specifications

Presents detailed technical specifications for the UV-2401/2501PC spectrophotometer, including performance data.

Shimadzu UV-2501 PC Specifications

General IconGeneral
Wavelength Accuracy± 0.3 nm
Wavelength Repeatability± 0.1 nm
Resolution0.1 nm
Data Sampling Interval0.1 nm
DetectorPhotomultiplier Tube (PMT)
Spectral Bandwidth0.1, 0.2, 0.5, 1, 2, 5 nm
Baseline Flatness± 0.001 A
Light SourceTungsten lamp (W)
MonochromatorDouble-beam
Data OutputRS-232C
Wavelength Range190 to 1100 nm