23(33)
4.4.1 Operation Procedure
Panel Code
Action
Description
Corresponding
Parameter
Parameters
Factory
Setting
Range
R01 Filter screen cleaning
F.06 3 secs.
0-99 secs.
R02 Waiting for motor stop
F.12 3 secs.
0-99 secs.
D
Absoring the materials
(vacuum breaking valve
action)
F.01 15 secs.
5-127 secs.
Absoring masterbatch
material (Close the
vacuum breaking valve
after the action is
stopped)
F.03 0% 0-100%
F.05 3 1-9
N01 Waiting time F.12 3 secs. 0-99 secs.
R11
Cleaning filter screen
The materials start to
discharge to the hopper
F.07 0 secs. 0-99 secs.
R12 Waiting motor stop
F.12 3 secs. 0-99 secs.
N02
Waiting materials
completely discharge to
the hopper
F.20 10 secs.
5-99 secs.
N03
Waiting for material
circulating suction
F.09 0 secs.
0-9990 secs.
P
Waiting for suction
confirmation

Related product manuals