Test in resistance.
TOOL: Multimeter.
Test the resistance of the winding. The compressor is fault if the resistance of winding
0(short circuit)or∞(open circuit
Familiar error:
1Compressor motor lock.
2Discharge pressure value approaches static pressure value .
3Compressor motor winding abnormality.
Notes
1Don’t put a compressor on its side or turn over.
2) Please assembly the compressor in your air conditioner rapidly after removing the plugs.
Don’t place the comp. In air for along time.
3Avoiding compressor running in reverse caused by connecting electrical wire incorrectly.
4Warning! In case AC voltage is impressed to compressor, the compressor performance will
below because of its rotor magnetic force decreasing.
4. INDUCTANCE
Familiar error:
1Sound abnormality
2Insulation resistance disqualification.
5. STEP MOTOR
5
4
2
1
Test in resistance.
TOOL: Multimeter.
Test the resistance of winding. The stepper motor is fault if the resistance of winding 0(short
circuit)or∞(open circuit.
6. FUSE
Checking continuity of fuse on PCB ASS’Y.
1) Remove the PCB ASS’Y from the electrical component box. Then pull out the fuse from the
PCB ASS’Y (Fig.1)