Limiter
Type Peak
Threshold ±16 dBu (at output)
Attack Time 2 ms
Recovery Time 300 ms
Indicator Lights red when limiting occurs
Input LEDs
Green on channel activation, red at 6 dB below clipping
Phantom Power
12 V DC open-circuit through 680 Ω resistors
Operating Voltage
SCM410 100-120 V AC rated nominal, 50/60 Hz, 100 mA (maximum)
SCM410E 220-240 V AC rated nominal, 50/60 Hz, 50 mA (maximum)
Mains Inrush Current (230 V AC, SCM410E only)
0.7 A Peak
Temperature Range
Operating Temperature -7° to 49° C (20° to 120° F)
Storage Temperature -29° to 74° C (-20° to 165° F)
Dimensions
44 x 219 x 267 mm (1 ¾ x 8 5/8 x 10 ½ in.), H x W x D
Net Weight
1.75 kg (3.86 lbs)
Certifications
SCM410: UL LISTED to UL 60065 and cUL LISTED to CAN/CSAC22.2 No. 60065-3 Canada.
SCM410E: Conforms to applicable European Union Directives. Low Voltage Directive, 2006/95/EC: Certified to EN
60065. Eligible to bear CE marking. Conforms to European EMC Directive 2004/108/EC. Meets Harmonized Stan-
dards EN55103-1:1996 and EN55103-2:1996 for residential (E1) and light industrial (E2) environments.