EasyManua.ls Logo

Shure U4D - RF Tuning and Voltage Verification

Shure U4D
47 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Shure U4D Dual Diversity UHF Receiver
21 25D1062 (AG)Service Procedures
Rf Tuning, Channel A
Dc Voltage Verification
C227
C242
P202
P202
P203
S201
ANTENNA A IN
P202
P202
P203
S201
ANTENNA B IN
DC VOLTMETER
DC VOLTMETER
(OFF)
(OFF)
J302
Figure 5. Dc Voltage Level Verification
1. Measure the dc voltage between the center pin of BNC
connector ANTENNA A IN, located on the receiver rear panel,
and ground. The voltage should measure 12.0 ± 0.5 Vdc.
2. Measure the dc voltage between the center pin of BNC
connector ANTENNA B IN, located on the receiver rear panel
and ground. The voltage should measure 12.0 ± 0.5 Vdc.