NOTICE
F
itting the system plug
If the system plug is not fitted, electrostatic discharge at the contacts may damage the
device.
b
Prevent electrostatic discharge at the contacts.
NOTICE
Enc
losure ratings IP 65 and IP67 only apply if the front connector is fitted.
If the system plug is not mounted, dirt, dust, or moisture may enter the device and
cause damage.
b
Fitting the system plug.
b
Prevent the entry of dirt, dust, and moisture.
Approach
1.
Make sure that the safety light curtain and system plug are disconnected from the
voltage supply while the system plug is being mounted.
2. Unpack the system plug.
3. Adjust the DIP switches as necessary.
4. Remove the protective film from the terminal compartment of the safety light
curtain.
5. Carefully mount the system plug on the terminal compartment of the safety light
curtain.
6. Use the 2 captive screws to screw the system plug onto the safety light curtain.
Torque 0.5 Nm ± 0.1 Nm.
Figure 26: Mounting the system plug
5 MOUNTING
40
O P E R A T I N G I N S T R U C T I O N S | deTec4 8027140/2021-11-04 | SICK
Subject to change without notice

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK C4P-SA12031A00 and is the answer not in the manual?

SICK C4P-SA12031A00 Specifications

General IconGeneral
BrandSICK
ModelC4P-SA12031A00
CategorySafety Equipment
LanguageEnglish

Related product manuals