Loading...
IO-Link interface
46 © SICK AG • Subject to change without notice • 8014868/YIF1/2020-10-19
9.3.4 SICK-specic–teach
Index
decimal
(hex)
Description Format Access Value range Example Remarks
130 (0x82) TEACH UINT16 W 0: Q1 DtO (Q1 dis-
tance to object)
1: Q2 DtO (Q2 dis-
tance to object)
2: Q1 near
3: Q1 far
4: Q1 center
5: Q2 near
6: Q2 far
7: Q2 center
8: Q1 ObSB (Q1
object between
sensor and back-
ground)
9: Q2 ObSB (Q2
object between
sensor and back-
ground)
10: Q2 4 mA
11: Q2 20 mA
12: Q2 0 V
13: Q2 10 V
14: Q2 Analog
center
15: Fine teach
+10 mm
16: Fine teach
-10 mm
A teach overwrites
a function that has
already been set with
a newly selected func-
tion. For values that
are not taught in again
and for an unsuccess-
ful teach, the old value
is retained.