EasyManua.ls Logo

SICK DS35

SICK DS35
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8014868/YIF1/2020-10-19 • © SICK AG • Subject to change without notice 45
IO-Link interface
Index
decimal
(hex)
Description Format Access Value range Example Remarks
66 (0x42) Bit lter for switch-
ing output/outputs
UINT8 R/W • 0: OFF
2: Filter depth 2
4: Filter depth 4
8: Filter depth 8
16: Filter depth 16
Filter depth 4:
Four consecutive
measured values
must exceed or
fall below the con-
gured switching
point in order
for the switching
output to react.
Denes how often in
succession the switch-
ing condition (e.g.
exceeding switching
point Q1 far) must
be fullled before the
status of the switching
output changes. The
bit lter aects only
the switching output
behavior, not the
process data or the
analog output.
Devices up to date
code 2033xxxx:
Writable only if the “0:
Expert” was selected
for index “103”.
Devices from date
code 2034xxxx:
Writing automatically
generates the selec-
tion “0: Expert” for
index “103”.
1) SICK-specic service data – sensor performance

Table of Contents

Related product manuals