8014868/YIF1/2020-10-19 • © SICK AG • Subject to change without notice 45
IO-Link interface
Index
decimal
(hex)
Description Format Access Value range Example Remarks
66 (0x42) Bit lter for switch-
ing output/outputs
UINT8 R/W • 0: OFF
2: Filter depth 2
4: Filter depth 4
8: Filter depth 8
16: Filter depth 16
Filter depth 4:
Four consecutive
measured values
must exceed or
fall below the con-
gured switching
point in order
for the switching
output to react.
Denes how often in
succession the switch-
ing condition (e.g.
exceeding switching
point Q1 far) must
be fullled before the
status of the switching
output changes. The
bit lter aects only
the switching output
behavior, not the
process data or the
analog output.
Devices up to date
code 2033xxxx:
Writable only if the “0:
Expert” was selected
for index “103”.
Devices from date
code 2034xxxx:
Writing automatically
generates the selec-
tion “0: Expert” for
index “103”.