EasyManua.ls Logo

SICK EtherNet/IP SIG350

SICK EtherNet/IP SIG350
82 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Resource HTTP
Method
Description
/parameters
/{index}/value
GET Read out of parameter values of a specific device
by means of the index
/parameters
/{index}/subindices
/{subindex}/value
GET Read out of parameter values of a specific device
by means of the index and subindex
/parameters
/{index}/value
POST Writing of a parameter value using the index
/parameters
/{index}/subindices
/{subindex}/value
POST Writing of a parameter value using the index and
subindex
Events
/events GET Read out of all events for a specific device
/vendor
Table 33: Vendor-specific JSON settings(/iolink/v1/vendor/masters/{masternum-
ber})
Resource HTTP
Method
Description
/diagnostics /value GET Read out of average value of the master
/ports/{portnumber}/
statistics/current
GET Read out of minimum and maximum current values
at the specific port
/ports/{portnumber}/
statistics/voltage
GET Read out of minimum and maximum voltage values
at the specific port
/ports/{portnumber}/
statistics/temperature
GET Read out of minimum and maximum temperature
values at the specific port
/ports/{portnumber}/
diagnostics
/current
GET Read out of actual current values at the specific
port
/ports/{portnumber}/
diagnostics
/voltage
GET Read out of actual voltage values at the specific
port
/ports/{portnumber}/
diagnostics
/temperature
GET Read out of actual temperature values at the spe‐
cific port
8.2.1.5 Status code and error messages
Errors may occur when processing HTTP requests. Several errors are defined.
The following rules apply to troubleshooting:
If multiple errors occur while processing the request, only the first detected error is
responded to.
If no REST API commands are available, error 103 is returned.
Error messages are structured as follows:
{
“code”: 102,
“message”: “Internal communication error”
}
The following table provides an overview of the possible error codes:
8 OPERATION
48
O P E R A T I N G I N S T R U C T I O N S | Sensor Integration Gateway - SIG350 8027834./2022-06-10 | SICK
Subject to change without notice

Table of Contents

Related product manuals