Name Value Description
CMDCPY 0/1/2/3/4/5 0: No command
1: Auto-Read
2: Auto-Write
3: Read
4: Write
5: Read UID
Antenna status 0/1 0: RF field off
1: RF field on
RSSI RSSI signal level of the transponder: 0= weak, … , 7= strong
Error code see "Error codes", page 53
Alarm2 0/1 0: Alarm2 off
1: Alarm2 on
Alarm1 0/1 0: Alarm1 off
1: Alarm1 on
Address First memory block in which the command was executed (in Read UID mode only)
System time Received time stamp (in Read UID mode only)
Time interval Period for which the transponder was in the detection range (only in Read UID mode)
Process Data Out (PDO)
Table 10: PDO
Byte offset 255 253-254 252 251 248-250
Byte0 START Antenna
status
Command
Type [Subindex] Boolean [1] Boolean [2] Unsigned integer 3 [3]
Byte offset 243-247 240-242
Byte1 RFU Number of blocks
Type [Subindex] Unsigned integer 5 [4] Unsigned integer 3 [5]
Byte offset 232-2391
Byte2 RFU
Type [Subindex] Unsigned integer 8 [6]
Byte offset 224-238
Byte3 Address
Type [Subindex] Unsigned integer 8 [7]
Byte offset 0-223
Byte4 ... 31 UserMemory 0-27
Type [Subindex] Unsigned integer 224 [8 ... 35]
OPERATION 8
8025309/1KDE/2023-12-19 | SICK O P E R A T I N G I N S T R U C T I O N S | RFH5xx
39
Subject to change without notice