EasyManua.ls Logo

SICK RFH5 Series

SICK RFH5 Series
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RFH505-1004301 RFH510-1004301 RFH515-1004301
Housing color Blue, silver Blue
Clamping bracket:
black
Mounting In metal environments: non-flush
Device mounting:
2 x M18 nuts, 2 x
spring washers
Tightening torque:
max. 25Nm
Device mounting:
2 x M30 nuts, 2 x
spring washers
Tightening torque:
max. 70Nm
Clamping bracket
Drill holes:
2 x 5.5mm, round
2 x 5.5mm x
5mm, slot
Fixing screws (M5):
Tightening torque:
max. 2.5Nm
Orientation of the
antenna can be
changed.
2)
Mounting of male
connector on device:
Tightening torque:
max. 0.6Nm
MTTF >756years
3)
Enclosure rating IP67
4)
IP68
4)
Protection class
(Class 2)
Safety EN62368-1:2014-08
Weight 37g
5)
87g
5)
108g
6)
Dimensions (∅ x H) M18mm x 63.5mm M30mm x 63.5mm 40mm x 40mm x
67mm
7)
1)
Bracket is included with delivery.
2)
By 90° referring to the longitudinal axis of the device.
3)
Continuous operation at ambient operating temperature +25°C. 322years at +40°C, 41years +80°C.
4)
EN/ETSI 301 489-1, para 8.2. The test method shall be performed in accordance with EN55022.
5)
Including fixing nuts and spring washers.
6)
Including clamping bracket. With bracket 88g.
7)
Including the protruding electrical connection, see "Device view", page 14.
12.3.1 Installation notes
RFH505 (M18) / RFH510 (M30)
Figure 18: RFH505, RFH510: distances required to prevent mutual interference with parallel
mounting of several devices as well as from the environment
TECHNICAL DATA 12
8025309/1KDE/2023-12-19 | SICK O P E R A T I N G I N S T R U C T I O N S | RFH5xx