NOTE
The input and output blocks can be moved to the workspace to achieve a better routing
and overview.
Figure 16: Connections
Connect your logic blocks with drag & drop with the inputs and outputs. First click
on the triangle on the input, hold the line and connect it to a triangle of the logic
block.
Please note to use always the upper inputs first, starting at A, then B, then C. In
case you use only two inputs please use always the top two inputs A+B and not e.
g. B+D.
Please note whether the values are Integer or Boolean it is only possible to
connect Integer with Integer and Boolean with Boolean. Boolean values have a
black triangle. Integer values are easily identifiable by a red triangle.
Figure 17: Possible connections
By clicking on logic block you get information about the possible connections to this
individual block.