y
x
Example:
Safe suppression of the background
White background (90 %)
Black object (6 % remission)
Set sensing range x = 500 mm
Needed minimum distance to white
background y = 10 mm
0
10
(0.39)
20
(0.79)
0
Minimum distance in mm (y) between the set sensing
range and white background (90 % remission)
Distance in mm (inch)
Recommended sensing range for
the best performance
30
(1.18)
y
x
800
(31.50)
600
(23.62)
400
(15.75)
200
(7.87)
2
6%/6%
6%/90%
33
6%/6%
6%/90%
6%/6%
6%/90%
1
Figura 10: Curva caratteristica, WTM10L-xxxxx1
0
Distance in mm (inch)
1
2
3
C/D
A B
Recommended sensing range for
the best performance
800
(31.50)
600
(23.62)
400
(15.75)
200
(7.87)
25
25
700
500
25
300
Figura 11: WTM10L-xxxxx1
1
Oggetto nero, coefficiente di riflessione 6%, Modalità 1: Velocità
2
Oggetto nero, coefficiente di riflessione 6%, Modalità 2: Standard
3
Oggetto nero, coefficiente di riflessione 6%, Modalità 3: Precisione
A Distanza di lavoro min. in mm
B Distanza di lavoro max. in mm
C Campo visivo
D Impostazione della soglia di commutazione dell'intervallo per l'eliminazione dello
sfondo
blu Intervallo di distanza di lavoro raccomandato per massime prestazioni
Tabella 8: WTM10L-xxxxx2, Short Range
WTM10L-xxxxx2, Short Range
ISTRUZIONI PER L’USO
156
I S T R U Z I O N I P E R L ’ U S O | WTM10L 9382969/2024-02-23 | SICK
Contenuti soggetti a modifiche senza preavviso
it