EasyManua.ls Logo

SICK WTM10L - Dimensional Drawings

SICK WTM10L
376 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Digital output
WTM10L-xxxxx1xxxxxxxxxxxxxxxxx WTM10L-xxxxx2xxxxxxxxxxxxxxxxx
Output current I
max.
≤ 100 mA ≤ 100 mA
Circuit protection B, D
1)
B, D
1)
Response time 1.8 ms (Mode 1 - Speed)
5 ms (Mode 2 - Standard)
15 ms (Mode 3 - Precision)
2)
1.8 ms (Mode 1 - Speed)
5 ms (Mode 2 - Standard)
15 ms (Mode 3 - Precision)
2)
Switching frequency 275 Hz (Mode 1 - Speed)
100 Hz (Mode 2 - Standard)
30 Hz (Mode 3 - Precision)
3)
275 Hz (Mode 1 - Speed)
100 Hz (Mode 2 - Standard)
30 Hz (Mode 3 - Precision)
3)
1)
B = inputs and output reverse-polarity protected
D = outputs overcurrent and short-circuit protected
2)
Signal transit time with resistive load
3)
With light / dark ratio 1:1
8)
Valid for Q\ on Pin2, if configured via software
Mechanical data
WTM10L-xxxxx1xxxxxxxxxxxxxxxxx WTM10L-xxxxx2xxxxxxxxxxxxxxxxx
Enclosure rating IP67, IP69 IP67, IP69
Ambient temperature, operation –10 °C ... +55 °C –10 °C ... +55 °C
11.2 Dimensional drawings
24.1
(0.95)
M12
19.6
(0.77)
28.95
(1.14)
1
5
76
57
(2.24)
20.3
(0.8)
3.2
(0.13)
12.7
(0.5)
21.2
(0.83)
R
1
.
6
33.2
(1.31)
25.4
(1)
2
3
4
18
(0.71)
Figure 24: WTM10L-xxxxxxxxxxxxV
1
Preferred direction of the target object
2
Center of optical axis, receiver
3
Center of optical axis, sender
4
Connection
5
Fixing hole Ø 3,2 mm
6
Display and setting elements
7
Zero-point measurement range
OPERATING INSTRUCTIONS
64
O P E R A T I N G I N S T R U C T I O N S | WTM10L 9382969/2024-02-23 | SICK
Subject to change without notice
en

Table of Contents