ECO FILTER – OPERATION AND MAINTENANCE MANUAL V 1.4 Page 41
Fig. 1
4. In particular, check the exciter (D), spring (C), piston (B) assembly moves free from obstacles or dirt due
to incorrect purification of compressed air. Also check the valve holes are not obstructed by dirt and the
piston stop is well clean
5. Make sure the discharge system (A) is free form dirt and the holes are not obstructed
6. If necessary, replace the damaged parts and reassemble the components following the reverse procedure
7. Check coil and compressed air pipes for correct connections
8. Open the compressed air supply to the filter and switch on the filter switchboard
9. With the stopped machine (switched off motor fan), perform a manual cleaning cycle to check there is no
air venting and the cleaning system has been correctly assembled (contact the Sideros Engineering
technical support)
10. Check the door seal making sure there are no cracks, crushing and discontinuity which might
compromise its perfect tightness
11. Replace the door and re-tighten the perimeter screws.
A
B
C
D