ECO FILTER – OPERATION AND MAINTENANCE MANUAL V 1.4 Page 52
THE CLEANING
SYSTEM DOES NOT
WORK
Insufficient compressed air
Check the building’s compressed
air network for correct operation
Electric trouble in the control unit
Ask the Sideros technical support
for the intervention of a technician
SMOKE COMING OUT
OF THE ROOF
Poorly tightened cartridges on reels
Tighten the cartridges all the way
Burnt or damaged cartridge
Replace immediately. Contact the
Sideros technical support for
spares.
FREQUENT TRIPPING
OF THE THERMAL
PROTECTION
Shorted motor
Ask the Sideros technical support
for the spare and the intervention
of a technician
Motor fan rotation in the wrong direction
Reverse two of the three power
wires on the switchboard
Too low calibration of the protection
Open the switchboard and set the
protection to correct values
BLOWING OUT OF
POWER SUPPLY FUSES
AT STARTUP
Motor fan rotation in the wrong direction
Reverse two of the three power
wires on the switchboard
Protection fuses not suitable for the application
Replace with properly sized motor
starting fuses.
9. Taking out of service
Should the machine and/or its components be stored and kept for a long period before commissioning to
avoid damages and deteriorations, make sure that:
▪ The electric mechanisms and structural parts are not damaged and the painted parts and machined
surfaces are not scratched;
▪ Before storing them, protect the structural parts and machined surfaces with antioxidant products;
▪ The materials can be stored up to a maximum of two years in a weather-protected environment with a
maximum relative humidity of 80% and temperatures between 15 °C and +60 °C;
▪ In case of storage for over two years, ask the manufacturer for preservation procedures;
▪ Should these values change during storage, preliminary checks must be performed before starting the
machine (see following paragraph);
▪ If temperature exceeds or drops below the given values and/or relative humidity is higher than 80%,
arrange protections with barrier sacks and hygroscopic salts;
▪ For outdoor storage, provide: