EasyManua.ls Logo

Siemens 1PH818 - Connection Lead & Terminal Box

Siemens 1PH818
198 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Procedure
1. Loosen 4 screws 2 and remove the protective grille 1.
2. The screws 2, contact washers 3 and anti-loss washers 4 stay on the protective grille.
3. Join the lter unit. Consisting of: Protective grille 1, fastening parts 2, 3, 4, lter cage 5 and
lter 6. Make sure that the lter is inserted in the centre and overlaps the sheet metal ring of the
lter cage 5 .
4. Fasten the complete lter unit to the fan, observe tightening torques
assembly centrifugal fans
design GR.
Fan with lter unit
Replace lter
1. Loosen 4 screws 2 and remove the complete lter unit from the fan.
2. Separate the protective grille 1 from the lter cage5 and remove the lter 6. The four screws
2, contact washers 3 and anti-loss washer 4 remain respectively on the protective grille 1.
3. Reassemble the lter unit with new lter according to DIN EN 779 - G3 as described in "Filter unit
assembly and fasten to the fan.
4.4 Connection lead & terminal box
Information
In demanding environments (wet areas, open air installation) all connections must incorporate water
drainage curves. To ensure that water cannot penetrate through to the controller housing from the
connections install a terminal box lower than the motor.
Do not coat connection components!
Coating connecting cables, cable glands and electronics covers (e.g. by
painting, lacquering, powder-coating), is not permissible without consulting
ZIEHL-ABEGG!
Painting the cover is only permissible with paints approved by ZIEHL-ABEGG!
Assembly instructions ECblue Mounting
L-BAL-F065-GB 1617 Index 004 Part.-No. 00702801-GB
13/28
177

Table of Contents

Related product manuals