ET 200M
SIMATIC
Distributed I/O device
ET
200M
Operating Instructions
04/2022
EWA
-4NEB7806006-09
Preface
Product overview
1
Brief instructions on
commissioning
2
Assignment planning
3
Installation
4
Connecting
5
Commissioning
6
Maintenance and service
7
Functions
8
Interrupt, error and system
messages
9
Technical Specifications
10
Compatibilities between
the IM 153-x
A
Order Numbers for the ET
200M
B

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Siemens 6ES7153-4AA01-0XB0 and is the answer not in the manual?

Siemens 6ES7153-4AA01-0XB0 Specifications

General IconGeneral
BrandSiemens
Model6ES7153-4AA01-0XB0
CategoryIndustrial Equipment
LanguageEnglish

Summary

Brief Instructions on Commissioning

Commissioning on PROFIBUS DP

Provides a step-by-step guide for commissioning the ET 200M using PROFIBUS DP.

Assignment Planning

Configuration possibilities for PROFIBUS DP

Covers configurations with IM 153-1, parameter assignment with HART, configurable FM, and FOC networks.

Configuring the mechanical structure

Covers horizontal/vertical installation, clearance measurements, and module arrangement rules.

Configuring the electrical structure

Details general rules, supply voltage, 24V DC supply, and protection against electrical influences.

Installation

Installation

Details steps for installing the mounting rail, modules, and concluding work.

Setting the PROFIBUS address

Explains how to set the unique PROFIBUS address for each bus node on the PROFIBUS DP.

Connecting

Connecting PROFIBUS DP

Details how to connect the bus connector and fiber-optic cable for PROFIBUS DP.

Connecting PROFINET IO

Explains how to connect the supply voltage and PROFINET IO to the IM 153-4 PN interface module.

Wiring the power supply and modules

Provides wiring rules for power supply, IM 153-x, front connectors, and shielded cables.

Commissioning

Maintenance and Service

Replacing the Power Supply Module

Provides instructions on removing and installing a power supply module for the ET 200M.

Replacing the IM 153-1

Details the procedure for removing and installing the IM 153-1 interface module.

Replacing the IM 153-2 or IM 153-2 FO

Covers removing and installing IM 153-2 and IM 153-2 FO modules, including redundant systems.

Replacing IM 153-4 PN

Provides steps for removing and installing the IM 153-4 PN interface module, including replacement procedures.

Replace modules without the function Change During Operation

Explains how to remove and install modules without the 'Change During Operation' function.

Replace modules with the function Change During Operation

Details the procedure for replacing modules while the ET 200M is operating using the 'Change During Operation' function.

Updating the IM 153-x

Covers when to update, how to obtain firmware, and methods for updating IM 153-x modules.

Functions

Interrupt, Error and System Messages

PROFIBUS DP

Covers diagnostics with LED display, slave diagnosis, station statuses, and master PROFIBUS address.

PROFINET IO

Details diagnostics using LED display, diagnostic messages, evaluating interrupts, and channel diagnostics for PROFINET IO.

Technical Specifications

Compatibilities between the IM 153-x

Related product manuals