Grounding screw M5 for potential equalization connection
Figure 4-9 Rear of the Basic PN connection module
Setting the box ID
You can use rotary coding switches S1 and S2 to set a unique ID on any connection module for
station identi󹪝cation purposes.
Use a screwdriver to set the IDs.
The setting is entered in hexadecimal format. Values in the decimal format between 0 and 255
can be entered.
By way of an example, the 󹪝gure below illustrates address 27H, which corresponds to decimal
address 39.
Rotary coding switch for higher-order bits (S1)
Rotary coding switch for lower-order bits (S2)
Figure 4-10 Example for address "27H"