Only available in EXPERT mode.
For cyclical switch commands the switching on time
is set by logical “OR“ of programs of all types. A fixed
cycle of ON and OFF time then operates within those
limits. The cycle always starts with the ON time. The
cycle duration and the ON time within the cycle are
the same length for all switching times. The cycle
duration and the ON time can be set independently
in one-second increments. If the switching time is
shorter than the cycle duration, the cycle will be
shortened accordingly. The ON time will remain
unchanged. If the switching time is actually shorter
than the ON time, the ON time will be shortened
accordingly.



 
15:00:00 15:10:00 15:20:00 15:30:00
15:32:00
Relais Channel 1
Program 1
Program n
Cycle function
1
2
+
Cell disposal
Warning: Elektrical shock - Disconnect all power from the device before dismantling the
module and replacing the battery.
Always use a Li cell type battery (LiMnO2) CR2477, 3V high temperature type min +85 °C