UMSITRAPDS3-1 Model Designations and Specifications
November 2010
9-3
TABLE 9-1 Model 7MF4033, Model Designation
Pressure transmitter, two-wire, series DSIII, 7MF4033-
-
Measuring cell filling Measuring cell cleaning
Silicone oil Standard
1
Inert liquid Grease-free
3
Span
0.01 To 1 bar g (0.15 To 14.5 psi g)
B
0.04 To 4 bar g (0.58 To 58 psi g)
C
0.16 To 16 bar g (2.32 To 232 psi g)
D
0.63 To 63 bar g (9.14 To 914 psi g)
E
1.6 To 160 bar g (23.2 To 2320 psi g)
F
4.0 To 400 bar g (58.0 To 5802 psi g)
G
Wetted parts materials
Seal diaphragm Process connection
Stainless steel Stainless steel
A
Hastelloy® Stainless steel
B
Hastelloy Hastelloy
C
Version as diaphragm seal
Y
Process connection
• Connection shank G1/2A to EN 837-1
0
• Female thread 1/2-14 NPT
1
• Oval flange made of stainless steel
- Mounting thread 7/16-20 UNF to EN 61518
2
- Mounting thread M10 to DIN 19213
3
- Mounting thread M12 to DIN 19213
4
• Male thread M20 x 1.5
5
• Male thread 1/2-14 NPT
6
Non-wetted parts materials
• Housing die-cast aluminum
0
• Housing stainless steel precision casting
3
Version
• Standard version
1
• International version, English label inscription and documentation in 5 languages on CD
2
Explosion protection
Without
A
• With ATEX, type of protection:
- Intrinsic safety (EEx ia)
B
- Explosion proof (EEx d)
D
- Intrinsic safety and explosion-proof enclosure (EEx ia + EEx d)
P
- Ex nA/nL (Zone 2)
E
- Intrinsic safety, explosion-proof enclosure and dust explosion protection (EEx ia +
EEx d + Zone 1D/2D)
R
• With FM + CSA, type of protection: Intrinsic safety and explosion proof (is + xp)
N C
Electrical connection / cable entry
• Screwed gland PG 13.5; adapter
A
• Screwed gland M20 x 1.5
B
Screwed gland 1/2-14 NPT
C
• Han 7D plug (plastic housing) includes mating connector
D
M12 connector (metal)
F
Display
• Without (digital indicator hidden, setting: mA)
1
• With visible digital indicator, setting: mA
6
• With customer specified digital indicator and setting, order code Y21 or Y22 required
7
Additional selections and data on next page.