EasyManua.ls Logo

Siemens 7MF4433 - Page 181

Siemens 7MF4433
222 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
UMSITRAPDS3-1 Model Designations and Specifications
November 2010
9-23
Influence of static pressure
• on the zero point (0.15* r) % per 100 bar (1450 psi)
- 20 mbar (0.29 psi)-measuring cell (0.15 % r)% per 32 bar (464 psi)
• on the span 0.2% je 100 bar (1450 psi)
- 20 mbar (0.29 psi)-measuring cell 0.2% je 32 bar (464 psi)
Rated operating conditions
Degree of protection (to EN 60529) IP65
Process temperature
• Measuring cell, silicon oil filling -40 to +100°C (-40 to +212°F)
• Measuring cell, inert filling liquid -20 to +100°C (-4 to +212°F)
• In conjunction with dust explosion
protection
-20 to +60°C (-4 to +140°F)
Ambient conditions
• Ambient temperature, digital indicators -30 to +85°C (-22 to +185°F)
• Storage temperature -50 to +85°C (-58 to +185°F)
• Climatic class, condensation Permissible
• Electromagnet compatibility To EN 61326 and NAMUR NE 21
Design
Weight, approximate, without options 4.5 kg (9.9 lb)
Housing material Low copper die-cast aluminum, GD-AISi 12 or stainless steel precision casing, mat.
No. 1.4408
Wetted parts materials
• Seal diaphragm Stainless steel, mat. No. 1.4404/316L or Hastelloy C276, mat. No. 2.4819, Monel,
mat. No. 2.4360, tantalum or gold
Measuring cell filling Silicone oil or inert filling liquid; max. 160 bar g (2320 psi g) with oxygen
measurement
Process connection Female thread 1/4-18 NPT and flange connection with mounting thread M10 to DIN
19213 or 7/16-20 UNF to EN 61518
Power Supply U
H
Terminal voltage at transmitter 10.5 to 45 Vdc
10.5 to 30 Vdc in intrinsically-safe mode
Certificate and approvals
See Table 9-20
HART communication
HART communication 230 to 1100
Protocol HART Version 5.x
Software for computer SIMATIC PDM