EasyManua.ls Logo

Siemens 7MF4433 - Page 185

Siemens 7MF4433
222 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
UMSITRAPDS3-1 Model Designations and Specifications
November 2010
9-27
Flanged Level Transmitter Accessories
Mounting flange, mounted directly on transmitter, two-wire, 7MF4812-
Mounting Flange:
Directly mounted on SITRANS P, DSIII series pressure transmitter (converter part)
3
Flange Nominal diameter Nominal pressure
Connection per DN 80 PN 40
D
EN 1092-1 DN 100 PN 16
G
PN 40
H
Connection per 3-inch Class 150
Q
ASME B 16.5 Class 300
R
4-inch Class 150
T
Class 300
U
Other version, add in plain text: nominal diameter and nominal pressure
Z J1Y
Wetted parts material
Stainless steel 316L:
A
Stainless steel 316L coated with:
- PFA
D
- PTFE
E 0
- ECTFE
F
Monel 400, material No. 2.4360
G
Hastelloy B2, material No. 2.4617
H
Hastelloy C276, material No. 2.4819
J
Hastelloy C4, material No. 2.4610
U
Tantalum
K
Other version, add in plain text: material in contact with medium and sealing face
Z K1Y
Tube length
Without (Flush mount)
0
50 mm (1.97 inches)
1
100 mm (3.94 inches)
2
150 mm (5.90 inches)
3
200 mm (7.87 inches)
4
Other version, add in plain text: tube length
9 L1Y
Filling liquid
Silicone oil M5
1
Silicone oil M50
2
High-temperature oil
3
Halocarbon oil (for O
2
measurement)
4
Glycerin/water
6
Food oil (FDA listed)
7
Other version, add in plain text: filling fluid
9 M1Y
Additional selections and data below.
Add "-Z" to the order number and add Order Code(s).
Order Code
Flame flashover lock-out
A01
Manufacturer test certificate M according to DIN 55350, Part 18, and ISO 8402
C11
Acceptance test certificate according to EN 10204
C12
Vacuum-proof version (for use in low pressure range)
V04
Calculation of span of associated transmitter, enclose completed questionnaire
Y05