SITRANS P300 (7MF8.23.. 7MF8.24.. 7MF8.25..)
26 A5E03434759-01, 08/2011
Gauge pressure input, with flush-mounted diaphragm
HART PROFIBUS PA or Foundation Fieldbus
Measured variable Gauge pressure
Span Maximum
operating
pressure
MAWP (PS)
Maximum test
pressure
Measuring
range
Maximum
operating
pressure
Maximum test
pressure
0.01 …
1 bar g (0.15
… 14.5 psi g)
4 bar g
(58 psi g)
6 bar g
(87 psi g)
1 bar g
(14.5 psi g)
4 bar g
(58 psi g)
6 bar g
(87 psi g)
0.04 …
4 bar g (0.58
… 58 psi g)
7 bar g
(102 psi g)
10 bar g
(145 psi g)
4 bar g
(58 psi g)
7 bar g
(102 psi g)
10 bar g
(145 psi g)
0.16 …
16 bar g (2.3
… 232 psi g)
21 bar g
(305 psi g)
32 bar g
(464 psi g)
16 bar g
(232 psi g)
21 bar g
(305 psi g)
32 bar g
(464 psi g)
0.63 …
63 bar g (9.1
… 914 psi g)
67 bar g
(972 psi g)
100 bar g
(1450 psi g)
63 bar g
(914 psi g)
67 bar g
(972 psi g)
100 bar g
(1450 psi g)
Span (continuously
adjustable) or measuring
range, max. operating
pressure and max. test
pressure
Depending on the process connection, the span may deviate from these values.
Absolute pressure input, with flush-mounted diaphragm
HART PROFIBUS PA or Foundation Fieldbus
Measured variable Absolute pressure
Span Maximum
operating
pressure
MAWP (PS)
Maximum test
pressure
Measuring
range
Maximum
operating
pressure
Maximum test
pressure
43 …
1300 mbar a
(17 ...
522 inH
2
O)
2.6 bar a
(38 psi a)
10 bar a
(145 psi a)
1300 mbar a
(522 inH
2
O)
2.6 bar a
(38 psi a)
10 bar a
(145 psi a)
0.16 …
5 bar a
(2.3 …
73 psi a)
10 bar a
(145 psi a)
30 bar a
(435 psi a)
5 bar a
(73 psi a)
10 bar a
(145 psi a)
30 bar a
(435 psi a)
1 … 30 bar a
(14.5 …
435 psi a)
45 bar a
(653 psi a)
100 bar a
(1450 psi a)
30 bar a
(435 psi a)
45 bar a
(653 psi a)
100 bar a
(1450 psi a)
Span (continuously
adjustable) or measuring
range, max. operating
pressure (in accordance
with 97/23/EC Pressure
Equipment Directive) and
max. test pressure (in
accordance with
DIN 16086)
Depending on the process connection, the
span may differ from these values
Depending on the process connection, the
measuring range may differ from these values
Output
Output
HART PROFIBUS PA or Foundation Fieldbus
Output signal 4 … 20 mA Digital PROFIBUS-PA or
Foundation Fieldbus signal