EasyManua.ls Logo

Siemens AGM60.4A9 - Output Terminal Loading

Siemens AGM60.4A9
30 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
18/30
Smart Infrastructure CC1N7544en
21.05.2021
Technical Data (cont´d)
Total contact loading:
Rated voltag
e
A
C 120 V,
50 / 60 Hz
Unit input current (safety loop) from:
- Fan motor contactor
- Ignition transformer
- Fuel valves
- Oil pump / magnetic clutch
(optional via AGM60
)
Max. 5 A
Individual contact loading:
Fan motor contactor
Rated voltage
AC 120
V,
50 / 60 H
z
Rated current 1.6 A pilot duty output declaration to
UL372
Power factor
Cos >0.4
Alarm output
Rated voltage
AC 120 V, 50 / 60 Hz
Rated current
1 A
Power factor
Cos >0.4
Ignition transformer
Rated voltage
AC 120 V, 50 / 60 Hz
Rated current 1.6 A pilot duty output declaration to
UL372
or
250 VA ignition output declaration to
UL372
Power factor
Cos >0.2
Fuel valves
Rated voltage
AC 120 V, 50 / 60 Hz
Rated current 1.6 A pilot duty output declaration to
UL372
Power factor
Cos >0.4
Operati
on display
Rated voltage
AC 120 V, 50 / 60 Hz
Rated current
0,5 A
Power factor
Cos >0.4
Safety valve (magnetic clutch / oil pump)
Rated voltage
AC 120 V, 50 / 60 Hz
Rated current 1.6 A pilot duty output declaration to
UL372
Power facto
r
Cos >0.4
Connections for pressure switch
Rated voltage
AC 120 V, 50 / 60 Hz
Rated current
1.5 mA
Power factor
---
Power supply for pressure switch
-
max / POC (X5
-
02 pin 3 or X22
-
02 pin 3)
IaMax
<10 mA
Fuel feedback to LMV36 (X31
-
02 pin 1 or X31
-
02
pi
n 2)
IaM
ax
<10 mA
Accuracy of output voltage
±
1 %
Terminal loading
«Ou
t
puts»
Analog output / load
ou
t
put X74 pin 3

Other manuals for Siemens AGM60.4A9

Related product manuals