Technical specifications
CP 5711
26 Operating Instructions, 02/2018, C79000-G8976-C283-05
Technical specifications of the CP 5711
Permitted ambient conditions
Operating conditions Temperature
(EN 60068-2-1+2)
Temperature change, maximum
0 ... +60°C
≤10 K/h
Relative humidity
(EN 60068-2-78)
95%, 16 h at 30°C no condensation
Rapid temperature change
(EN 60068-2-14)
3 h at 0°C, 3 h at 60°C
5 cycles
Storage and transportation conditions Temperature
(EN 60068-2-1+2)
Temperature change, maximum
-40 ... +70°C
≤ 20 K/h
Rapid temperature change when
damp
(EN 60068-2-30)
+25...+55°C at 97% no condensation
Rapid temperature change
(EN 60068-2-14)
-40 ... +70°C, 2 cycles
Vibration, operating
(EN 60068-2-6)
Frequency 10 ... 58 Hz
Frequency 58 ... 500 Hz
Number of cycles
0.075 mm amplitude
10 m/s
2
Acceleration
10/axis
Shock, operating
(EN 60068-2-27)
Half sine
Time
Number of shocks
50 m/s
2
(5 g)
30 ms
100/axis
Design, dimensions and weight
Module format USB module
Weight
Approx. 300 g
Dimensions (W x H x D) in mm
85 x 137 x 35
Electromagnetic compatibility
Emission
to EN 55022
to FCC
Class B
Class A
Immunity On signal cables
Surge to EN 610004-5
Burst to EN 61000-4-3
±2 kV
±2 kV
to discharge of static electricity
Contact discharge to IEC 61000-
4-2
±6 kV
to radiated radio frequencies
to EN 61000-4-3
10 V/m at 80 MHz ... 2 GHz
10 V/m, 80% amplitude modulation at
1 kHz
to EN 61000-4-6
10 kHz ... 80 MHz