EasyManuals Logo

Siemens CP 5711 User Manual

Siemens CP 5711
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #26 background imageLoading...
Page #26 background image
Technical specifications
CP 5711
26 Operating Instructions, 02/2018, C79000-G8976-C283-05
Technical specifications of the CP 5711
Permitted ambient conditions
Operating conditions Temperature
(EN 60068-2-1+2)
Temperature change, maximum
0 ... +60°C
≤10 K/h
Relative humidity
(EN 60068-2-78)
95%, 16 h at 30°C no condensation
Rapid temperature change
(EN 60068-2-14)
3 h at 0°C, 3 h at 60°C
5 cycles
Storage and transportation conditions Temperature
(EN 60068-2-1+2)
Temperature change, maximum
-40 ... +70°C
≤ 20 K/h
Rapid temperature change when
damp
(EN 60068-2-30)
+25...+55°C at 97% no condensation
Rapid temperature change
(EN 60068-2-14)
-40 ... +70°C, 2 cycles
Vibration, operating
(EN 60068-2-6)
Frequency 10 ... 58 Hz
Frequency 58 ... 500 Hz
Number of cycles
0.075 mm amplitude
10 m/s
2
Acceleration
10/axis
Shock, operating
(EN 60068-2-27)
Half sine
Time
Number of shocks
50 m/s
2
(5 g)
30 ms
100/axis
Design, dimensions and weight
Module format USB module
Weight
Approx. 300 g
Dimensions (W x H x D) in mm
85 x 137 x 35
Electromagnetic compatibility
Emission
to EN 55022
to FCC
Class B
Class A
Immunity On signal cables
Surge to EN 610004-5
Burst to EN 61000-4-3
±2 kV
±2 kV
to discharge of static electricity
Contact discharge to IEC 61000-
4-2
±6 kV
to radiated radio frequencies
to EN 61000-4-3
10 V/m at 80 MHz ... 2 GHz
10 V/m, 80% amplitude modulation at
1 kHz
to EN 61000-4-6
10 kHz ... 80 MHz

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens CP 5711 and is the answer not in the manual?

Siemens CP 5711 Specifications

General IconGeneral
BrandSiemens
ModelCP 5711
CategoryConference System
LanguageEnglish

Related product manuals