22
en
Water connection
The appliance is only approved for heating water ■
with a specific electric resistance of ≥ 1 300 cm
at 15 °C. Your water utility company can give you
information about the specific water resistance.
Installation
Ensure the axial fit of the connection pipes in the ■
nozzles.
Tighten the union nuts on the nozzles with an ■
open-end wrench and counter hold with a suit-
able open-end wrench.
The T-piece (for the pressurized connection) ■
and flexible connection hose are available
commercially.
Use an unpressurized tap for the unpressurized ■
connection, e. g. the tap available as a special
accessory (Single-lever mixer tap BZ13061,
Two handle fixture BZ13051).
Exchange the perlator from the tap fixture with
■
the supplied aerator to change the spray pattern
of the tap.
Controlling temperature
The supply temperature (probably lower in winter)
and pressure fluctuations can influence the tem-
perature of the water leaving the tap.
Turn the valve slowly in the closed direction for
■
higher temperatures (F1).
Add cold water for lower temperatures (
■F2).
pressurized (closed) unpressurized (open)