EPAC300-M50 SERIES USER’S MANUAL
AUGUST 2005 PAGE 21 OF 46
4.3.1 EPAC300-M51 I/O Assembly Unique Features
NEMA “A” connector for service power and VM signal to monitor
4.3.2 EPAC300-M52 I/O Assembly Unique Features
NEMA “A” connector for service power, VM signal to monitor and I/Os
NEMA “B”, “C” and “D” connectors for inputs and outputs
4.4 ITEM 4: Internal 1200 BPS NEMA Port 3 FSK Modem (optional)
Plugs into I/O Assembly
Held in place by chassis handle pocket wall
Two mechanical programming straps, cut circuit board trace to program
Factory set for 2-wire operation, cut JP1 strap for 4-wire operation
Factory set for anti-stream disabled, cut JP2 strap to enable
May be replaced with cable to modem installed in expansion slot
Figure 8: Modem Programming Straps
4.5 ITEM 5: ATC Modem Blank Cover
OR- Fiber Optic Module
Covers the two slots reserved for standard ATC modems
Breaks apart for 0, 1 or 2 modems installed
4.6 ITEM 6: Modem Cover Fasteners
Four #6 stainless steel flathead screws per cover
Attaches Item 5 to Item 1
4
-
WIRE: CUT JP1
ANTI-STREAM: CUT JP2