Siemens Industry, Inc. A6V11416604 2018-07-11 1 / 4
s
Smoke Control Compliant
Actuating DXR
DXR2.E10PL-102BK
DXR2.E10PLX-102BK
DXR2.M10PL-102BK
DXR2.M10PLX-102BK
Installation Instruction
Product Numbers
Accessories
985-124
499 OHM Resistor Assembly Kit
Smoke Control Compliance
Parts for Smoke Control Compliance
540-155K ,
540-155D
550-002K
TR100VA004
Smoke Control Compliance
The following instructions and information apply if used for
smoke control sequence.
Install Smoke Control Listed products, enclosure and trans-
former (see Parts for Smoke Control Compliance section for
more information).
Input Rating:
- 24V 60 HZ 72 VA
Digital Output (DO) are the only I/O suitable for smoke con-
trol application. Digital Output (DO) Electrical Ratings:
24 Vac, 6VA per DO/maximum 40 VA total.
Connection from the DXR2 to the field panel is a maximum
4000 feet, 24 AWG minimum.
Wiring Range:
- Transformer: primary 14 AWG
- 24 Vac Input Power: 14 to 18 AWG
- DO: AI: 18 to 20 AWG
- DI: 18 AWG
- LAN: 20 to 24 AWG
KNX port (11 and 12) not used or connected for smoke
control application
All circuits are power limited; FLN is RS-485 or
Ethernet.
See the following documents for more information on
configuring smoke control applications:
Smoke Control Systems Application and Engi-
neering Manual (125-1806)
Smoke Control System Application Guide
(125-1816)
NFPA and UL Standards Relevant to Smoke
Control System Application Guide (125-1817)
NOTE:
The 24 Vac relay module is not
applicable for smoke control
application.
A6V11416604
6
5
4
3
2
1
Question and Answer IconNeed help?

Do you have a question about the Siemens DXR2.E10PL-102BK and is the answer not in the manual?

Siemens DXR2.E10PL-102BK Specifications

General IconGeneral
ModelDXR2.E10PL-102BK
Number of Inputs10
Mounting TypeDIN Rail
ManufacturerSiemens
TypeController
Input Voltage24 V AC/DC
Communication ProtocolBACnet/IP

Summary

Smoke Control Compliance

Parts for Smoke Control Compliance

Lists required components for smoke control, including controller enclosures and resistors.

Wiring Range Specifications

Details wire gauge requirements for transformer primary, 24 Vac input, digital outputs, and LAN connections.

Smoke Control Application Guidelines

Provides instructions for installation, input/output ratings, connection limits, and notes for smoke control sequences.

Dimensions

Physical Dimensions

Provides detailed measurements and diagrams of the actuator unit.

Mounting Instructions

Damper Shaft and Blade Setup

Guides determination of damper shaft size and setting damper blade rotation.

Actuator Installation and Torque

Details manual override switch usage, adjustment lever positioning, and torque specifications.

Mounting Bracket Attachment

Explains how to attach the mounting bracket, including alignment and orientation.

Wiring Diagram

MS/TP and IP Connections

Illustrates upstream and downstream wiring for MS/TP and IP communication.