EasyManua.ls Logo

Siemens HG61234

Siemens HG61234
2 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Note: This instruction outlines recommended
installation procedure.
1. Turn OFF and lock out the power supplying the Safety
Switch.
2. Turn the Safety Switch OFF.
Installation Instructions for Ground Lug Kit
3. HG656 Kit Only: If mounting Ground Lug to a painted
surface, remove and discard protective plate and pro-
tective plate mounting screw to expose metal, see
Fig. 2.
4. Position Ground Assembly over existing hole as shown
in Fig. 1 for HG61234 or Fig. 2 for HG656.
5. Insert green thread rolling screw in mounting hole and
torque to 29 lb.-ins. for Kit HG61234 or 64 lb.-ins. for
Kit HG656.
6. Close cover before supplying power to this switch.
Fig. 2Fig. 1
© 2000 Siemens Energy & Automation, Inc.
SAFETY INSTRUCTIONS
Item: Ground Lug Kit,
Catalog No. HG61234 & HG656
For use with:
30-600 Amp
VBII Safety Switches
Page 1 of 2
Pc. No. 500202A02
s
Siemens Energy & Automation, Inc.
Bellefontaine, Ohio 43311 U.S.A.
For questions call 1-800-241-4453 or our web site:
http://www.sea.siemens.com/dpd
Hazardous voltage.
Will cause death or serious
injury.
Turn off and lock out all power
supplying this Safety Switch
before installing kit.
Replace the covers and shields
before restoring power to switch.
Ground Lug Kit HG61234
Ground Lug Kit HG656
BdafWUf[hWB^SfW
7`U^aegdWi[fZ
BS[`fWV?ag`f[`Y
EgdXSUWA`^k
B^SfW?ag`f[`YEUdWi
7`U^aegdWi[fZBS[`fWV
?ag`f[`YEgdXSUWA`^k
9dag`V>gY
9dag`V>gY
?ag`f[`YEUdWi
>[`WEZ[W^V
>[`W4SeW3eeW_T^k
Ground Lug
Protective Plate
(Enclosure with
Painted Mounting
Surface Only)
Plate Mounting Screw
(Enclosure with Painted
Mounting Surface Only)
Line Shield
Line Base Assembly
Ground Lug
Mounting Screw
Question and Answer IconNeed help?

Do you have a question about the Siemens HG61234 and is the answer not in the manual?

Siemens HG61234 Specifications

General IconGeneral
BrandSiemens
ModelHG61234
CategorySecurity Sensors
LanguageEnglish

Summary

Ground Lug Kit Installation

General Safety Warning

DANGER warning regarding hazardous voltage, death, or serious injury. Turn off and lock out power before installing.

Safety Instructions Note

Note stating that these instructions outline the recommended installation procedure.

Turn OFF and Lock Out Power

Step 1: Turn off and lock out the power supplying the Safety Switch.

Turn Safety Switch OFF

Step 2: Turn the Safety Switch OFF.

HG656 Kit Painted Surface Mounting

Step 3 (HG656 Kit Only): Prepare painted surface by removing protective plate and screw.

Position Ground Assembly

Step 4: Position Ground Assembly over existing hole as shown in Fig. 1 or Fig. 2.

Install Green Thread Rolling Screw

Step 5: Install green thread rolling screw with specified torque for HG61234 or HG656.

Close Cover

Step 6: Close cover before supplying power to the switch.