Service Manual
6-219
Configuring the system specifically for the client
Table of the System’s Programming Codes
Music source for
the MOH Group
088 1 or 2 - MOH Group 0 - No music
1 - Internal – MIDI
2 - Internal - Wave
3 - External
4 - External – extension
# instead of
group
0 - No
music
Music Source
Extension
089 1 or 2 - MOH Group Extension or
∗ - to delete
# instead of
group
None
External music
source - Extension
assignment
064 extension or
∗ - to delete
Automatic None
Setting the time for
an external room
monitor
169 Connection time:
01 to 99 seconds
Automatic 10
seconds
Interdigit Pause
Time Setting
227 1 to 5 seconds Automatic 2
seconds
Types of caller lists 049 1 - external
2 - Internal and external
Automatic 2 - Inter-
nal and
external
Deleting digits
from the caller list
171 Initial sequence of digits (up to
6 digits)
5-second
timeout
None
Date/Time -
Manual setting
114 DD - Day, from 1 to 31
MM - Month, from 1 to 12
YY - Year, from 00 to 99
HH - Hour, from 00 to 23
MlMl - Minutes, from 00 to 59
Automatic
Automatic Update
of Date/Time
038
∗ - to enable
# - to disable
Automatic ∗ - to
enable
Callback for exter-
nal calls via ISDN
221
∗ - to enable
# - to disable
Automatic ∗ - to
enable
Call Charge Unit 195 Value: 000000000 to
999999999
+
Comma position: 0 to 3
Automatic factor -
00001
slot - 0
Multiple for call
charge factor
042 1 - Factor 1
2 - Factor 2
Pulse multiplier: 000 to 254 Automatic 001 -
Value 1
Call charge factor
for extensions
043 extension 1 - Default
2 - Factor 1
3 - Factor 2
# instead of
extension
1 -
Default
Call charge value
by extension
197 extension Value: 000000000 to
999999999
+
Comma position: 0 to 3
Automatic factor -
00001
slot - 0
Programmed
Functions
Code Intermediate data Data to be programmed Completing
data entry
Default