Modules
3-64 Service Manual
Expansion modules (EB)
Connector assignments for the EB 012 and EB 010 modules
Table 3-11 EB 012 and EB 010 Connector assignments
Contact X1 Connector X2 Connector X3
Connector
X4 Connector
1 Connection to
MB through
backplane
Connector
a1 - extension 1 a5 -
extension 5
a9 - extension 9
2 b1 - extension 1 b5 -
extension 5
b9 - extension 9
3 a2 - extension 2 a6 -
extension 6
a10 - extension 10
4 b2 - extension 2 b6 -
extension 6
b10 - extension 10
5 a3 - extension 3 a7 -
extension 7
a11 - extension 11
6 b3 - extension 3 b7 -
extension 7
b11 - extension 11
7 a4 - extension 4 a8 -
extension 8
a12 - extension 12
8 b4 - extension 4 b8 -
extension 8
b12 - extension 12
Note 1: X4 Connector uses contacts 5 through 8 on the EB 012 only.