Siemens I-T-E Sensitrip MD Series User Manual

Siemens I-T-E Sensitrip MD Series
63 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Bulletin SIB2.7-8
Sensitrip®
MD & ND-Frame
Information and
Instruction Guide
I-T-E
®
Molded Case
Circuit Breakers
Question and Answer IconNeed help?

Do you have a question about the Siemens I-T-E Sensitrip MD Series and is the answer not in the manual?

Siemens I-T-E Sensitrip MD Series Specifications

General IconGeneral
Poles1, 2, 3
Trip UnitThermal-Magnetic
Voltage Rating240 VAC
Interrupting Capacity14 kA @ 240 VAC
MountingPlug-in
StandardsUL 489

Summary

I-T-E Molded Case Circuit Breakers

Sensitrip MD & ND-Frame Information and Instruction Guide

Essential information and instructions for Sensitrip MD & ND-Frame circuit breakers.

Safety Precautions and Warnings

Hazardous Voltages and Qualified Personnel

Details dangers of hazardous voltages and requirements for qualified personnel.

Important Notices

Authorized and Qualified Personnel

Defines qualifications for personnel working with the equipment.

DANGER: Hazardous Voltages

Highlights severe risks associated with hazardous voltages.

General Information

Circuit Breaker Operation

Explains the operational mechanism and handling of circuit breakers.

Installation Instructions

Safety Instructions

Outlines recommended safety procedures for installation.

Installation of Breaker

Provides step-by-step guidance for installing the circuit breaker.

Trip Adjustments

Time-Current Characteristic Curve

Illustrates time-current trip characteristics for breaker coordination.

Adjustable Continuous Amps Switch

Details the adjustment of the continuous amps setting.

Adjustable Long Time Delay

Explains how to set the long time delay for trip adjustments.

Adjustable Short Time Pickup

Guides on adjusting the short time pickup setting.

Adjustable Short Time Delay

Details the selection of short time delay settings.

Adjustable Instantaneous Trip Switch

Explains how to adjust the instantaneous trip settings.

Adjustable Ground Fault Pickup

Guides on setting the ground fault pickup parameters.

Time Current Curves

600-1000A With Short Time Delay Set on Fixed Time

Details time-current curves for specific settings and breaker ratings.

1200A With Short Time Delay Set on Fixed Time

Provides time-current curves for 1200A breakers with fixed short time delay.

600-100A With Short Time Delay Set on I²t

Shows time-current curves for specific settings using I²t delay.

1200A With Short Time Delay Set on I²t

Details time-current curves for 1200A breakers with I²t delay.

600-100A Without Short Time Settings

Illustrates time-current curves when short time settings are not used.

1200A Without Short Time Settings

Provides time-current curves for 1200A breakers without short time settings.

Ground Fault Trip Data

Presents specific data for ground fault trip functions.

Let-Thru Curves

Internal Accessories

Mechanical and Electrical Check

Outlines checks for shunt trip and undervoltage trip accessories.

Rotary Handle Operator

Max-Flex™ Flange-Mount Handle Operator

TELEMAND® Electric Motor Operator

Door Latch Mechanism

Neutral Sensing Transformer

Universal Test Kit (TS-31)

Operating Instructions

Details the operational steps for using the TS-31 test kit.

Testing

Describes the various tests that can be performed with the TS-31 kit.