CC1N7101en
27.11.2008
Building Technologies
HVAC Products
7
101
Burner Controls LME...
Burner controls for the supervision of 1- or 2-stage gas or gas / oil burners of
small to medium capacity, operation, with or without fan in intermittent.
The LME… and this Data Sheet are intended for use by OEMs which integrate the
burner controls in their products.
Use, features
LME… burner controls are used for the startup and supervision of 1- or 2-stage gas or
gas / oil burners in intermittent operation. The flame is supervised by an ionization
probe or flame detector QRA… with ancillary unit AGQ3…A27 for gas / oil forced draft
burners or blue–burning flames with blue-flame detectors QRC...
In terms of housing dimensions, the LME... are identical with the LGB… and LMG…
burner controls (refer to «Type summary»).
- For gas burners with or without fan to EN 298: 2003
- For gas burners with fans conforming to EN 676
- For oil burners to EN 230: 2005
- Undervoltage detection
- Air pressure supervision with functional check of the air pressure switch during
startup and operation
- Electrical remote reset facility
- Multicolor indication of fault status and operational status messages
- Limitation of the number of repetitions
- Accurate control sequence thanks to digital signal handling
- Controlled intermittent operation after 24 hours of continuous operation
Supplementary documentation
Product Range Overview LME…............................................................................ Q7101
Use
Features
Question and Answer IconNeed help?

Do you have a question about the Siemens LME21.350A1 and is the answer not in the manual?

Siemens LME21.350A1 Specifications

General IconGeneral
Number of Outputs2
Mounting TypeDIN Rail
Mains Voltage230 V AC
Mains Frequency50/60 Hz
Poles1
ApprovalsCE, UL
StandardsEN 298

Summary

Use, features

Features

Lists the key functionalities and capabilities of LME burner controls.

Warning notes

Engineering notes

Installation notes

Electrical connection of flame detectors

Commissioning notes

Safety check to be carried out

Specific safety checks required during commissioning.

Burner operation with simulated loss of flame

Testing burner response to simulated flame failure.

Burner operation with simulated air pressure failure

Testing burner response to simulated air pressure loss.

Type summary (other types of burner controls on request)

Technical data

Flame supervision with ionization probe

Flame supervision with AGQ3...A27 and UV detector QRA...

Ancillary unit AGQ3...A27

Flame supervision with QRC... (only LME23...)

Functions

Control sequence in the event of fault

Resetting the burner control

Limitation of repetitions

Operation, indication, diagnostics

Diagnostics of the cause of fault

Connection diagram and control sequence LME11...

Connection diagram and control sequence LME21...

Connection diagram and control sequence LME22... / LME23...

Connection diagram and control sequence LME41...

Connection diagram and control sequence LME44...

Related product manuals