EasyManua.ls Logo

Siemens MC35 Terminal - Send USSD Response (cmdType 18)

Siemens MC35 Terminal
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote-SAT User's Guide
P R E L I M I N A R Y
MC35_SAT_01_V01.01a - Preliminary Page 45 of 64 15.11.2001
1.5.2.5 AT^SSTR Remote-SAT Response – Send USSD (18)
Write command
AT^SSTR=18,
<status>
The TA indicates if the Send USSD command has been cancelled by the user.
Response
OK
Parameters
<cmdType> 18 – Proactive command ID, see Table 1.
<status> Unsigned Integer, range 0-255
0 Command performed successfully
20 USSD/SS Transact terminated by user
32 TA currently unable to process command
132 TA currently unable to process command because
screen is busy.
Notes:
Used only for confirmation of customer application status
Reference
Siemens