1.5.2.9 AT^SSTR Remote-SAT Response – Display Text (33)
Write command
AT^SSTR=33,
<status>
The TA can respond with a move through proactive session, or provide
additional information.
Response
OK
Parameters
<cmdType> 33 – Proactive command ID, see Table 1
<status> Unsigned Integer, range 0-255
0 Command performed successfully
16 Proactive SIM session terminated by user
17 Backward move in the proactive SIM session requested
by the user
18 No response from user
32 TA currently unable to process command
132 TA currently unable to process command because
screen is busy.
Notes:
User confirmation to clear the displayed text.
Reference
Siemens
Note
Used to provide information to the ME, upon receiving a ^SSTGI response.