4. Right-click on the required IIS page (default: SinInt) and select "Edit Bindings".
The "Site Bindings" window opens. The port settings are listed.
Click "Add..."
The "Add Site Binding" window opens.
Make the required settings, e. g.:
Type: "https"
IP address: "<server ip address>" or "<host name>"
Port: 443
SSL certificate: Click "Select" to select the certificate.
Note:
Do not activate the "Require Server Name Indication" checkbox. Otherwise communication
problems may occur.
Click "OK".
- OR-
If HTTPS is to be configured with the use of a DNS name (host name), open the "Site
Bindings" window.
Click "Edit...".
The "Edit Site Binding" windows opens
Fill the "Host name" field in IIS.
Setting up an encrypted connection
5.1 Certificate on the server
Manage MyResources, Optimize MyProgramming /NX-Cam Editor
Installation Manual, 12/2019, A5E44672080B AE 113