2
Mounting and installation
RF components
34
Siemens Operator / Room / Auxiliary devices CE1U2358en_04
Building Technologies 2014-09-26
NOTICE
Establish
RF connection while unmounted and near the RF module (BSB).
The base unit powers the RF module (BSB).
The devices battery supply must be activated (remove the battery protective
strip).
2
1
1 Button
2
LED
1. Press the button on the RF module (BSB) for at least 8 seconds.
a The LED on the RF module (BSB) blinks rapidly.
2. Press the button on the transmitter of the RF outside sensor for at least 8
seconds.
a This LED also blinks rapidly.
- The connection is established when the LED on the RF module
(AVS71.390) extinguishes.
- The LED of the RF module BSB (AVS71.393) lights again after 5 seconds
(operating state "On").
3. Press the button on the RF outside sensor again briefly until the LED
extinguishes.
RF connection
Establishment