EMI and Environmental Type Tests 27
Test Description Test Levels Severity Levels
DC Power Ports 2 kV
AC Power Ports 2 kV
Signal ports 5 kV (Fail-Safe Relay output)
DC Power Ports 5 kV
IEC 60255-5 HV Impulse
AC Power Ports 5 kV
IEEE 1613 Type Tests
NOTE
The RUGGEDCOM RS900G meets Class 2 requirements for an all-fiber configuration and Class 1
requirements for copper ports.
Description Test Levels
Enclosure Contact ± 8 kVESD
Enclosure Air ± 15 kV
Radiated RFI Enclosure ports 35 V/m
Signal ports ± 4 kV @ 2.5 kHz
DC Power Ports ± 4 kV
AC Power Ports ± 4 kV
Fast Transient
Earth Ground Ports ± 4 kV
Signal ports 2.2 kV common mode @ 1 MHz
DC Power Ports 2.5 kV common and differential mode @ 1 MHz
Oscillatory
AC Power Ports 2.5 kV common and differential mode @ 1 MHz
Signal ports 5 kV (Failsafe Relay)
DC Power Ports 5 kV
HV Impulse
AC Power Ports 5 kV
Signal ports 0.5 kV (Failsafe Relay)
DC Power Ports 2 kV
Dielectric Strength
AC Power Ports 2 kV
Environmental Type Tests
Test Description Test Levels Severity Levels
IEC 60255-21-1 Vibration 2g @ 10-150 Hz Class 2
IEC 60255-21-2 Shock 30g @ 11 ms Class 2