Installing the Device
2.6.2Connecting Low DC Power
1. Connect the positive wire from the power source to the positive/live (+/L) termi-
nal on the terminal block.
1
Positive/Live (+/L) Terminal
2
Negative/Neutral (-/N) Terminal
3
Surge Ground Terminal
4
Braided Ground Cable
Figure2.6 Terminal Block Wiring
2. Connect the negative wire from the power source to the negative/neutral (-/N)
terminal on the terminal block.
3. Using a braided wire or other appropriate grounding wire, connect the surge
ground terminal to the chassis ground connection. The surge ground terminal is
used as the ground conductor for all surge and transient suppression circuitry in-
ternal to the unit.
4. Connect the ground terminal on the power source to the chassis ground termi-
nal on the device.
2.6.2 Connecting Low DC Power
To connect a power source to the low DC power supply, do the following:
NOTICE
Electrical hazard – risk of damage to equipment
RUGGEDCOM RS900G
Installation Manual, 06/2020, C79000-G8976-1025-07