Chapter 4
System Administration
RUGGEDCOM WIN
User Guide
46 Clearing Alarms
Parameter Description
Severity Synopsis:  {Clear, Critical, Major, Warning}
Displays the severity of the alarm.
Category Synopsis:  {Restart, Communication, RF, Hardware, Security, Environmental, Redundancy,
Services, Link Status}
Displays the category for the alarm type.
Last Description Displays a message describing the alarm.
Last Update Time Displays the date and time of the most recent alarm.
Section4.10.2
Clearing Alarms
To clear alarms, do the following:
1. Navigate to Management» Alarms and Traps. The System Alarms screen appears.
Figure42:System Alarms Screen
2. Select an alarm from the Alarms table.
3. Click Clear Alarm/s.
Section4.11
Configuring the NTP Server
The RUGGEDCOM WIN can be used to take timing inputs from the base station and act as an accurate timing
source for other devices.
NOTE
Prior to enabling the NTP server, the Time Advertisement Enabled parameter must be set, on the GPS
screen in the base station. This parameter enables the NTP Server to work properly.
To enable the NTP server, do the following:

Table of Contents

Other manuals for Siemens RUGGEDCOM WIN5214

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens RUGGEDCOM WIN5214 and is the answer not in the manual?

Siemens RUGGEDCOM WIN5214 Specifications

General IconGeneral
BrandSiemens
ModelRUGGEDCOM WIN5214
CategoryWireless Router
LanguageEnglish

Related product manuals