9 MMC Connector Problems
Fault Symptoms
Customer: GRT:
MMC malfunction Tbd.
MMC connector Problems
Watch for oxidation and
damaged pads of the
MMC connector
caused by customer
SCRAP - has to be send
separately to WSC
not
oka
y
okay
Check the status of the
MMC connector visually
Use the resistor test
function of a multimeter
to check connection
between spring
contacts and soldering
contacts.
The value must be ~0
Exchange
MMC connector
Continue with
higher repair level
okay
not
oka
y
not
oka
y
- check for twisted or
bent contacts
- check for dry joints
Back to customer
without repair
Connector MMC
Use soldering iron to remove defective component. Avoid excessive heat! Watch surrounding
components! Resolder new component afterwards.
E-commerce order number: L50634-Z97-C415
E-commerce order name: CONNECTOR RS MMC X75; CONNECTOR RS MMC X75
Soldering temperature: ~ 360°C TIP Temp.
IRIS Diagnose Code: 4E000 Interfaces/ Memory Card Rerader
Attention: Avoid excessive heat in order not to damage the plastic material of the
connector (see problem SLIM-Lumberg connector)