EasyManua.ls Logo

Siemens S75 - IRDA Problems

Siemens S75
15 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Release 1.0
Technical Documentation
10/2005
TD_Repair_L2.5L_S75_R1.0.pdf Page 13 of 15
11 IRDA Problems
Fault Symptoms
Customer: GRT:
No infrared connection possible Tbd.
IRDA Problems
Watch for oxidation and
damaged pads of the
IRDA
caused by customer
SCRAP - has to be send
separately to WSC
not
oka
y
okay
Check the status of the
IRDA visually
Exchange
IRDA
Continue with
higher repair level
okay
not
oka
y
not
oka
y
- check for twisted or
bent contacts
- check for dry joints
Back to customer
without repair
IRDA
Use hot air blower to remove defective component. Avoid excessive heat! Watch surrounding
components! Resolder new component afterwards.
E-commerce order number: L36197-F5008-F492
E-commerce order name: IRDA 115.2 KBIT
Soldering temperature: ~ 360°C TIP Temp.
IRIS Diagnose Code: 41100 Interfaces / IRDA / No Function
41300 Interfaces / IRDA / Mechanical Damage
Company Confidential
2005©BenQ

Other manuals for Siemens S75

Related product manuals