Important additional soldering hints
The MMC Reader is located on the opposite of the SLIM-Lumberg connector.
Therefore the risk to damage the plastic material of this MMC-Reader is potentially high if excessive
heat is used while removal or soldering of the SLIM-Lumberg connector.
Please follow these instructions:
a) Remove the SLIM-Lumberg connector with a soldering iron and Desolder Wick
b) Clean the Pads afterwards
c) Solder the new connecter by using soldering iron under consideration of the max. allowed
temperature range.
Samples of critical area:
Lock mechanism damaged Lock mechanism OK
Lock mechanism damaged Lock mechanism OK